EXO has two low voltage interface ports (Port A and Port B) that allow you to connect external devices, which are then triggered based on events detected by EXO. As of July 15, 2024, you can configure how these ports behave.
Before Triggering events were previously hard coded to display the following behaviour:
High gas threshold
When EXO detected gas levels at or above the high gas threshold, Port A applied power. A device connected to Port A was activated. The port turned OFF when gas levels returned to normal.
Low gas threshold
When EXO detected gas levels at or above the low gas threshold, Port B applied power. A device connected to Port B was activated. The port turned OFF when gas levels returned to normal.
Starting July 15, you can now choose what kind of events trigger each port using your EXO’s Blackline Live configuration profile. Ports A and B can individually be configured to trigger on one or more of the following:
Normal port pin power behavior (apply power when triggered by an event)
The normal (untriggered) state for the power applied to the pins on the ports is as follows (Figure B):
When the port is triggered by an EXO event, the switches are activated to the following conditions (Figure C):
In your EXO configuration profile in Blackline Live, you can reverse this switch behavior. Each port can be independently configured for a port inversion option.
In the reversed option, the normal (untriggered state) has all the switches on all pins closed as shown in Figure C. On the triggering event the pin conditions reverse to the open positions shown in Figure B.
This option allows you to choose the normal and triggered conditions on Ports A and B depending whether you want your fail-safe mode to be with power or without power on those pins.
On the EXO configuration page in Blackline Live, the Interface ports section allows you to configure the desired behavior of EXO’s Interface ports.
NOTE:You can select one or more of these inputs to trigger each port.
In the Define how EXO will supply power section, you can change the power conditions on those ports from the normal Power applied on trigger, to Power removed on trigger.
Port Trigger synchronization
After a port is triggered, the port(s) are reset when the following conditions are met:
For more information on EXO ports and port configurations, refer to the EXO Technical User Manual.